A server room runs the same load at four in the morning in January as it does on the hottest afternoon of the year, and it fails expensively when it gets hot. Comfort cooling is not designed for that. Close control is, and the difference shows up the first time something goes wrong at a weekend.

  • Year roundno seasonal shutdown, ever
  • Redundancya second unit where downtime costs
  • Alarmsyou hear about it before the kit does

In short

CoolIn designs, installs and maintains cooling for server rooms, comms rooms and small data suites across Manchester and the North West, from a single rack in a cupboard to a room running on N+1 with remote monitoring.

Typical systems
Close control, in row, dedicated splits on rotation
Close control
From £9,000 installed
Comms cupboard
From £2,600 for a dedicated unit
Recommended range
18C to 27C at the rack inlet
Servicing
Usually four visits a year, not one
Monitoring
Temperature alarm to phone or email

Why it is a different job

Why a normal air conditioning unit is the wrong answer

This is the single most common thing we are asked to put right. A comfort unit will cool a server room, right up until the day it does not, and the way it fails is specific and predictable.

The load never stops

Comfort cooling is built for a room full of people that empties at six and is shut at the weekend. A server room is at full load every hour of every day, including the coldest week of the year. Run a domestic split like that and you are running it well outside what it was designed for.

Equipment rated for continuous duty

It will not run in winter

Most comfort units are not built to cool when it is near freezing outside, and will refuse to run or trip on low pressure. That is fine in an office, which wants heating in January. In a server room it means the cooling stops in the one situation where nobody is watching, and the room climbs.

Low ambient operation specified

One unit is one point of failure

When the single unit in the room fails, the clock starts immediately, and a small room with several racks in it heats up quickly. Two smaller units sharing the load, alternating so both stay exercised, means a failure is an inconvenience rather than an outage.

N+1 with lead and lag rotation

Nobody finds out until it is too late

Server rooms have no occupants to notice. Without a temperature alarm the first sign of a failure is usually kit shutting itself down, often on a Friday night. A sensor and an alert cost very little against what an unplanned outage costs.

Temperature alarm to phone or email

The options

What we install in a server or comms room

The right answer scales with what is in the room and what an hour of downtime costs you. A comms cupboard and a room of racks are different problems.

01

Close control cooling

Purpose built for technical spaces. Holds tighter temperature and humidity bands than comfort equipment, runs continuously year round, and is designed to handle the dry, high sensible load a room of servers actually presents.

02

N+1 redundancy

A second unit sized so either can carry the room alone, with a controller alternating lead and lag so both stay exercised and neither sits idle for months. Standard on any room where an outage has a real cost.

03

Dedicated splits on rotation

For a smaller comms room, two dedicated units specified for low ambient operation and alternated weekly. Considerably cheaper than close control and a sound answer where the room is a cupboard rather than a suite.

04

Monitoring and alarms

Temperature and, where it matters, humidity sensing with an alert to a phone or an email address. The cheapest part of the whole job and the part that most often turns a disaster into a callout.

Budget

What server room cooling costs

Installed prices covering equipment, labour, commissioning and handover. A technical room is priced on its heat load in kilowatts, on how much redundancy you want, and on where the condenser can go, so these are budget bands rather than quotations.

Guide prices, installed. Confirmed at site survey.

Comms cupboard

A rack or two, low criticality. Installed prices

  • Single dedicated unitfrom £2,600
  • Two units on rotationfrom £4,900
  • Temperature alarmfrom £320
  • Ventilation onlyper project

Server room

Several racks, business critical. Installed prices

  • Close control, single unitfrom £9,000
  • Close control, N+1 pairper project
  • Monitoring and alertingfrom £320
  • Quarterly service planfrom £229 per unit

Larger suite

Multi rack or high density. Installed prices

  • In row coolingper project
  • Containment and airflowper project
  • Plant replacementper project
  • Resilience upgradeper project

These are guide bands, not quotations. A server room quote starts from the actual heat load, which we work out from the connected load of the kit in the room rather than from its floor area. That number, plus whether you want redundancy, decides almost everything else. The survey costs nothing.

Operation and duties

Keeping a technical room reliable

The design gets you a room that works. These three are what keep it working, and they are where most of the rooms we inherit have been let down.

Temperature and humidity targets

The widely used industry guidance recommends keeping the air entering the equipment between roughly 18C and 27C. Running colder than that wastes electricity without making the hardware any happier.

Humidity matters in both directions. Too high and you risk condensation on cold surfaces. Too low and static becomes a genuine hazard when somebody works in the racks.

What actually matters is the temperature at the rack inlet, not the reading on a wall thermostat across the room, which is why sensor position is part of the design.

Servicing frequency

A room running at full load every hour of the year needs looking at more often than an office. Most server rooms we maintain are on four visits a year, checking filters, coil condition, refrigerant charge, drain operation and the alarm itself.

Testing the alarm is the part most often skipped, and an alarm nobody has proved is not resilience.

Our commercial servicing plan covers quarterly attendance, and we test the failover on rooms running a lead and lag pair.

F-Gas duties

Close control systems hold more refrigerant than a comfort unit, so a server room crosses the 5 tonne CO2 equivalent threshold more readily than most spaces of its size. Past that line the operator has to arrange leak checks and keep records.

Automatic leak detection can extend the interval between manual checks on larger systems, which is worth knowing before specifying.

The thresholds in full are on the commercial page, and we work out where your system sits at survey.

How it works

Survey, fixed quote, fitted around you

A free survey, a written price with the heat load working shown, and a programme set around your hours. The four stages are the same on every commercial job and are set out in full on the commercial page, along with servicing plans and what to do about breakdowns.

We cool server and comms rooms across Manchester, Salford Quays, Warrington, Stockport and the wider North West, including Manchester, Salford, Stockport, Warrington and Liverpool. See every town we cover.

Other business types

We work in these too

Each sector has its own page, because a server room and a hair salon are genuinely different jobs. The commercial overview covers what applies to all of them.

Questions

What server rooms customers ask first

Can I just use a normal split unit in my server room?

For a small comms cupboard it can work, provided the unit is specified for low ambient operation so it still cools when it is near freezing outside, and provided you accept that a failure means downtime. Standard comfort equipment installed without that specification is the most common cause of the winter failures we get called to.

What temperature should a server room be?

Industry guidance recommends air entering the equipment between roughly 18C and 27C. Many rooms are run far colder than they need to be, which costs real money in electricity and gains nothing. The measurement that counts is at the rack inlet rather than on a wall.

Do I need two units?

It depends entirely on what an hour of downtime costs you. If the room only runs a switch and a file server, one properly specified unit plus an alarm is reasonable. If the business stops when the room stops, two units sized so either can carry the load alone is the only sensible answer.

What happens if the cooling fails overnight?

With no alarm, the room heats until the equipment protects itself or fails, and you find out on Monday. With a sensor and an alert you get a message while there is still time to open a door, bring in temporary cooling or shut things down in an orderly way. It is the cheapest resilience you can buy.

How often should it be serviced?

Usually four times a year rather than once. The load is constant, the run hours are far higher than comfort equipment, and the alarm needs proving as well as the cooling. Quarterly attendance is what our commercial plan is built around.

Can you cool a room that already has equipment running?

Yes. We plan the work so the room is never left without cooling for longer than it can safely tolerate, using temporary cooling during the changeover where the heat load makes that necessary. That sequencing is set out in the quote rather than improvised on the day.

Free survey

Tell us about the space and we will do the rest

Fill this in and an engineer will call you back the same working day. No sales visit, no pressure, and a written quote within 48 hours of the survey.

  • Survey and quote at no cost
  • Fixed price, valid for 60 days
  • Nothing to pay until the job is finished
  • Two year guarantee on our workmanship

Prefer to talk it through

07391 523255

We use your details to quote for this job and nothing else. No lists, no third parties.

WhatsApp Call us